Natural gas only — domestic houses and flats. For open-flued, room-sealed and flueless appliances within the scope shown below.
A) Appliance Arrangement & Details
For natural-gas appliances in domestic houses and flats. Choose the appliance and installation details below. If the input is gross, the calculator converts it approximately to net using gross ÷ 1.11. Check the manufacturer’s instructions and current guidance before using the result.
The next questions check whether these appliances can be assessed together.
Enter each appliance below, using “Add another appliance” for any extra ones. All must be in the same room.
This natural-gas route is limited to domestic houses and flats. Other choices need a separate assessment; this does not mean those installations are prohibited. Appliance and site requirements still need checking.
This is a specific exclusion, not an exclusion of every gas fire. Check the appliance documentation if you are unsure. For multiple appliances, answer for all appliances included in this calculation.
Scope: associated gas appliances must total no more than 70 kW net. The automatic check covers only the heat inputs entered here. Check the complete associated installation separately, including any appliances whose input is not entered in this calculation.
Include appliances in the room or compartment and any room supplying an open-flued compartment. Include room-sealed appliances when checking what is present. If anything is omitted or uncertain, a separate assessment is needed.
Space heating includes central-heating boilers, gas fires, air heaters and convectors. For an open-flued room calculation, all appliances in this group must provide space heating; sharing a flue category alone is not enough. The shared-compartment route has separate rules. Choose the arrangement that matches the appliance category and location you have selected.
Appliances in the same room
Enter each appliance separately. Add another row for every appliance sharing this room’s air supply. The calculator groups the open-flued space-heating inputs before comparing the ventilation requirements.
The listed types cover open-flued space heating (including central-heating boilers, eligible gas fires, air heaters and convectors), room-sealed appliances and domestic cookers. For another type, an uncertain type, or the special removed-partition arrangement with two similar fires, choose “Other appliance / not sure” for a separate assessment.
Room details for the cooking appliances
These answers apply to every cooking appliance entered above. Enter the room volume once.
For a single appliance, enter the appliance input. For multiple appliances of the same type, enter the total combined net input. For different appliance types, calculate each type separately and use the largest requirement.
B) Installation Details
For room installations, the assistant gives single-vent guidance where applicable. For compartments, high and low level ventilation is shown.
C) Site Conditions & Warnings
Answer the site questions that apply to this installation. Some answers produce a warning rather than change the calculated vent area.
For the open-flued air path, count the outside vent and the internal wall vents. Do not count the appliance compartment’s high and low vents.
Natural-gas scope: this calculator covers the ordinary room and compartment arrangements described in its questions. It does not design balanced compartments, special ducts, roof or underfloor air supplies, or alternative internal-kitchen ventilation. These need a separate assessment. For new or replacement open-flued appliances, the ventilation air path must not pass through a bathroom or shower room. Check appliance-specific requirements and any restrictions for sleeping accommodation.
Consider fans in other rooms too. Cooker hoods, tumble dryers and whole-house ventilation are examples; the check is not limited to extract fans in this room.
A competent person must assess the actual installation using the applicable instructions and guidance. A calculated vent area does not demonstrate satisfactory operation.
Check the instructions for the actual appliance and compartment arrangement. For multiple appliances, this answer must cover all of them. If any instructions are missing, unclear or different, choose the relevant check above rather than the general calculation.
Check the instructions for the actual appliance and compartment arrangement. For multiple appliances, this answer must cover all of them. If any instructions are missing, unclear or different, choose the relevant check above rather than the general calculation.
Results
Result generated on
Appliance input used
Ventilation guidance
Vent free area
Vent position
This assistant supports calculation checks and guidance prompts only. Results must be interpreted by a competent person in line with current guidance, manufacturer instructions, site conditions and professional judgement.
We take care to check our materials, but errors or omissions may still occur. This resource supports learning and practical calculations. It does not replace appropriate training, professional judgement, current standards or the appliance manufacturer’s instructions.
Check that the method and information apply to the installation you are working on. A calculated result or worked example does not establish that an installation is safe or compliant.
If you spot an error or an unexpected result, please contact TomKat so we can investigate. Your statutory rights are unaffected.
Disclaimer:
This tool is provided as guidance only and is intended to support domestic natural-gas appliance ventilation training and calculation checks. It does not replace formal training, manufacturer instructions, current standards, site-specific assessment, or professional judgement. Results must be interpreted by a competent person in line with current guidance and safe working practices. No liability is accepted for any loss, damage or incorrect use arising from reliance on this tool.
We use essential cookies to run this website and remember your choices. With your permission, Google Analytics measures visits and clicks on our shop recommendations. You can accept optional cookies, deny them, or choose your preferences. You can still browse, book and shop if you deny optional cookies, and change your choice using Manage consent.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
With your permission, Google Analytics uses cookies and online identifiers to measure website visits and clicks on selected shop recommendations. Google receives this information to provide analytics reports to TomKat. We use these reports to improve the website. See our Privacy Policy and Cookie Policy for details.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.